16 research outputs found

    Acute paranoid psychosis as sole clinical presentation of hepatic artery thrombosis after living donor liver transplantation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hepatic artery thrombosis is a devastating complication after orthotopic liver transplantation often requiring revascularization or re-transplantation. It is associated with considerably increased morbidity and mortality. Acute cognitive dysfunction such as delirium or acute psychosis may occur after major surgery and may be associated with the advent of surgical complications.</p> <p>Case presentation</p> <p>Here we describe a case of hepatic artery thrombosis after living-donor liver transplantation which was not preceded by signs of liver failure but rather by an episode of acute psychosis. After re-transplantation the patient recovered without sequelae.</p> <p>Conclusion</p> <p>This case highlights the need to remain cautious when psychiatric disorders occur in patients after liver transplantation. The diagnostic procedures should not be restricted to medical or neurological causes of psychosis alone but should also focus vascular complications related to orthotopic liver transplantation.</p

    Asthma in the elderly: what we know and what we have yet to know

    Get PDF
    In the past, asthma was considered mainly as a childhood disease. However, asthma is an important cause of morbidity and mortality in the elderly nowadays. In addition, the burden of asthma is more significant in the elderly than in their younger counterparts, particularly with regard to mortality, hospitalization, medical costs or health-related quality of life. Nevertheless, asthma in the elderly is still been underdiagnosed and undertreated. Therefore, it is an imperative task to recognize our current challenges and to set future directions. This project aims to review the current literature and identify unmet needs in the fields of research and practice for asthma in the elderly. This will enable us to find new research directions, propose new therapeutic strategies, and ultimately improve outcomes for elderly people with asthma. There are data to suggest that asthma in older adults is phenotypically different from young patients, with potential impact on the diagnosis, assessment and management in this population. The diagnosis of AIE in older populations relies on the same clinical findings and diagnostic tests used in younger populations, but the interpretation of the clinical data is more difficult. The challenge today is to encourage new research in AIE but to use the existing knowledge we have to make the diagnosis of AIE, educate the patient, develop a therapeutic approach to control the disease, and ultimately provide a better quality of life to our elderly patients

    A microfabricated interface for neural recording and stimulation.

    No full text
    Neural interfaces are microfabricated systems able to record and to stimulate regenerated and intact nerves. We present herein a microdevice fabricated in the framework of the ESPRIT INTER project 8897 which seems particularly attractive for basic research in neurophysiology and even for future clinical applications. The microsystem is a hybrid device comprising a silicon die, incorporating electrodes to establish electrical connection with the regenerated nerve, housed in a polymer guidance channel and connected to an implanted signal preprocessing integrated unit. The fabrication of microsystem components, their assembly and recent in vivo results are described

    Neural interfaces for regenerated nerve stimulation and recording.

    No full text
    A class of implantable, regeneration-type neural interfaces (NI's) for mammalian peripheral nerve recording and stimulation were developed using different fabrication processes and integrating purposely designed components. A typical NI comprises three main components: 1) a microfabricated silicon die incorporating a microelectrode array on multiple through-holes, 2) a polymer guidance channel housing the die, and 3) a flexible fiat cable connecting the die to an external electronic circuitry. The design and fabrication of the NI's were aimed at achieving long term, reliable implants by taking into careful account the biological, electrical, and mechanical requirements of the specific implant site. Different versions of the NI were fabricated and implanted between the severed ends of the sciatic nerve in a mammalian animal model (rabbit). Morphological and histological evidence showed that nerves regenerated through the NI's and electrophysiological results demonstrated the recovery of electrical functionality. Moreover, the NI's allowed stimulation of the regenerated nerve producing a visible leg/foot contraction. The NI's presented in this paper are being further improved in the authors' laboratories with the ultimate goal of allowing the control of nerve motor and sensory functions in future prosthetic devices
    corecore